MIL-STD Conducted Susceptibility Generators

Montena develops and manufactures pulse generators for MIL standards conducted susceptibility tests, according to MIL-STD-461 CS106, CS114, CS115 and CS116 test methods.

For better frequency range coverage, montena CS116 generator is offered in 3 versions with respectively 6, 9 and 17 frequencies.

The standard MIL-STD-1275 is also covered by 2 generators, for the versions D and E.

Advantages

  • Control software for fully automated test setup and measurement
  • CS116 generator with up to 17 test frequencies for more accurate susceptibility assessment
  • One single output for the POG-CS116 (all CS116 test frequencies and additional modules)
  • Modular approach for all budgets
  • Complete set of accessories for test and measurement available (probes, loads, etc..)
  • All generators can be ordered such as table top or 19” rack mounting versions

All designs can be adapted to the customer’s requirements, to fulfil other standards.

Specifications

The following standalone generators are proposed :

REFERENCE SPECIFICATIONS STANDARDS
PG-CS106 500 V / 100 A MIL-STD-461 F CS106
PG-CS115 0 – 2 kV MIL-STD-461 D/E/F CS115
IEC 61000-4-24 section 4
POG-CS116-6 10, 100 kHz, 1, 10, 30, 100 MHz MIL-STD-461 CS116, 6 frequencies
POG-CS116-9 10, 30, 100, 300 kHz, 1, 3, 10, 30, 100 MHz MIL-STD-461 CS116, 9 frequencies
POG-CS116-17 10, 18, 30, 56, 100, 180, 300, 560 kHz
1, 1.8, 3, 5.6, 10, 18, 30, 56, 100 MHz
MIL-STD-461 CS116, 17 frequencies
PG1275D 400 A MIL-STD-1275D, Imported and exported spikes and surges
PG1275E 16 A / 400 A MIL-STD-1275E,
Injected voltage spikes and surges
DM400 400 A external diode module MIL-STD-1275E Injected voltage surges

Montena has designed the POG-CS116 pulse generator to host additional pulse modules for CS106, CS115 pulse delivery beside the built-in CS116 damped sinusoidal pulse modules. These factory installed modules and the CS116 modules are all connected to the same generator output. This allows the execution of all test frequencies and pulse shapes without re-cabling or module exchange need.

The calibration as well as the measurement process is entirely automated. All settings and levels are recorded for measurement and test reports.

The POG-CS116 generator can host following additional modules:

REFERENCE CHARGING VOLTAGE REMARKS
M-CS106 500 V / 100 A Module CS106 to be plugged in the POG-CS chassis
M-CS115 0 – 2 kV Module CS115 to be plugged in the POG-CS chassis