montena technology sa
Route de Montena 89
1728 Rossens
Switzerland
Tel. +41 26 411 84 84
Fax +41 26 411 17 79
Montena proposes generators for conducted susceptibility tests, capable of injecting damped oscillatory waves up to 300 A. The test method with the optional coupling clamp is similar to the one described in MIL-STD-461 CS116 except that this new series of generators can produce much higher current levels.
The calibration as well as the measurement process is entirely automated. All settings and levels are recorded for the measurement and for the generation of a test report.
Typical current capabilities are given in the chart below. In this example, the generator can produce short-circuit currents up to 300 A (150 A in a 50 ohm load) at 12 distinct frequencies.
All designs can be tailored to meet individual customer requirements or standards.
REFERENCE | SPECIFICATIONS | STANDARDS |
PG-C201 | Damped oscillatory wave generator, frequency range: 10 kHz - 100 MHz, 12 frequencies, up to 150 A on a 50 ohm load | Custom design |
PG-C202 | Damped oscillatory wave generator, frequency range: 10 kHz - 100 MHz, 6 to 12 frequencies, up to 23 A on a 100 ohm load | MIL-STD-461 CS116 levels +7dB |