montena technology sa
Route de Montena 89
1728 Rossens
Switzerland
Tel. +41 26 411 84 84
Fax +41 26 411 17 79
CS101 specifies the conducted susceptibility test of equipment and subsystem AC and DC input power leads, in the frequency range of 30 Hz to 150 kHz.
CS109 conducted susceptibility test, Structure Current, 60 Hz to 100 kHz, is used to verify the ability of sensitive equipment and subsystems (1uV or better) to withstand structure currents.
RS101 is used to assess the radiated susceptibility of equipment and subsystem enclosures, including electrical cable interfaces, in the frequency range of 30 Hz to 100 kHz.
Montena offers a complete test solution for the three standards. Dedicated control software with a graphical user interface allows simple setup via scroll down menus to select the appropriate components. Calibration and measurement are designed to be fully automated, with reports generated afterwards.
EQUIPMENT | REFERENCE | SPECIFICATIONS | |
Frequency injection | Signal generator | SIG10M | 0 to 10 MHz |
Power amplifier | PA20K13A | 0 to 200 kHz frequency range | |
Coupling transformers | TR250K50A | 50 A, for CS101 | |
Radiating loop | SG12-RS101 | 30 Hz to 100 kHz, 15 A continuous for RS 101 | |
Test accessories | High power load | VR15-210 | Variable resistor to compensate the power current feedback into the amplifier |
Precision resistor | R0.5-200 | 0.5 Ω 200 W, resistor for calibration | |
LISN | LISN50-25 | Line impedance stabilization network 50 µH, 20 A | |
Decoupling capacitor | CC10-400 | Decoupling capacitor 10 µF | |
Field monitoring sensor | SCR4-RS101 | Single coil for calibration | |
Measurement equipment | Current probe | CT10000F | 50 A, 1 Hz to 20 MHz |
Oscilloscope | OD2C100M | 100 MHz bandwidth, 1 Gs/s, 2 channels | |
Software | Management of calibration, settings, tests and reports |