High-current damped oscillatory wave generators

Montena proposes generators for conducted susceptibility tests, capable of injecting damped oscillatory waves up to 300 A. The test method with the optional coupling clamp is similar to the one described in MIL-STD-461 CS116 except that this new series of generators can produce much higher current levels.

The calibration as well as the measurement process is entirely automated. All settings and levels are recorded for the measurement and for the generation of a test report.

Advantages

  • One single output for up to 12 test frequencies in the range 10 kHz - 100 MHz
  • Control software running on a PC allows fully automated calibration and test
  • Full set of accessories for test and measurement (probes, loads, etc..)

Typical current capabilities are given in the chart below. In this example, the generator can produce short-circuit currents up to 300 A (150 A in a 50 ohm load) at 12 distinct frequencies.

All designs can be tailored to meet individual customer requirements or standards.

REFERENCE SPECIFICATIONS STANDARDS
PG-C201 Damped oscillatory wave generator, frequency range: 10 kHz - 100 MHz, 12 frequencies, up to 150 A on a 50 ohm load Custom design
PG-C202 Damped oscillatory wave generator, frequency range: 10 kHz - 100 MHz, 6 to 12 frequencies, up to 23 A on a 100 ohm load MIL-STD-461 CS116 levels +7dB